Since 1994 Spirometry Filters for all brands - Nose Clips & Rubber MP - Koko Spriometers -  Wright Respirometer Sales, Repair & Calibration
Grace Medical Marketing, Inc.                       Call 800-672-7701    email: terry@gracemed.net


 _____________________________________________________________________________________________

Koko Spirometers



KOKO Spirometer - Full Function PC- Based - Product # 313105

Spirometry You Can Rely On

  • Features a 'Fleisch-Type' pneumotach for unparalleled accuracy and durability
  • Quick, simple and easy to use
  • Independently validated to exceed ATS 1994 recommendations for both ambient and BTPS conditioned air
  • Side-by-side, real-time flow/volume loop and volume/time graphics
  • Multiple incentive graphics for patient coaching. Intelligent automatic target value adjustment
  • Full customizable report format and content, predicted values, graphics  format and size, automated interpretation and challenge protocols
  • Trend analysis of patient results
  • Available with USB or serial port interfaces
  • Full network multi-user capability
  • Internet or direct dial up connectivity allows multiple offices to share patient data files

 

Koko USB Technical Specifications













Tests Performed: FVC, SVC, Pre- and Post- BD, MVV, Challenge
Parameters Measured
(in FVC test):  

Expiratory:
FVC, FEV.5, FEV.5/FVC%, FEV1, FEV1/FVC%, FEV3, FEV3/FVC%, FEV6, FEV6/FVC%, FEV1/FEV6%, PEFR, FEF25%, FEF50%, FEF75%, FEF25-75%, FEF.2-1.2, FEF75-85%, Tpeak(ms), Vext%, Vext(l), MET(s), Texp(l), Veot(l)

Inspiratory:
FIVC, FIV.5, FIV.5/FIVC, FIV1/FIVC, FIV3, FIV3/FIVC, PIFR, FIF50%, FIF25-75%, FIF.2-1.2, FIF50/FEF50, MIT(s), Tinsp(s)

Pneumotach: Brass Core Fleisch-type Pneumotachometer
Calibration: Three injection mode; one injection mode; Supports both one and three liter calibration syringes.
Filter Requirement: KoKoMoe (model #810000 or #819000)
Power Equipment: Power derived from USB port
Accuracy:  <+3% or 100 ml, whichever is greater; research grade accuracy of <1% can be set via calibration
Reproducibility: <+ 0.5% or 0.150 l, whichever is greater
Volume Range: +16 l
Flow Range: +16 l/s
Resistance: <1.5 cmH20/l/s when tested with KoKo Moe filter
Memory Storage: Unlimited – dependent on hard disc drive or network server capacity
Predicted Sets: Crapo 1981, Polgar (Pediatrics), ITS 1984, Knudson 1976/1983, ECCS 1983/1993, Hankinson (NHANES III) 2000, Toronto 1991,  Morris F 1988/1971, Gore (Australia) 1995, Pereira (Brazil) 1996, Dejsomritrutai (Thai) 1996, Miller 1996, Eigen (pre-school pediatrics), Viljanen/KLNW (Finland), Hendenstrom/Solymar (Sweden), Gulsvik (Norway), SEPAR (Spain), Forche (Austria), Hibbert (Pediatrics), Shands (mixed), Wang (Pediatrics), Pereira (Brazil) 2002, Knudson 1976.    
Interpretation Algorithm: McKay (ATS / ARRD 1991); ITS; Modified Ellis
Reports: Unlimited self defined, multiple preset designs
Incentive Graphics: Candles, sailboat, 3 pigs, flying kite, brick wall.
Connectivity: Network compatible interface to electronic medical records via HL7. Client version can automatically share data with nSpire Health Raptor pulmonary lab analyzers.
Dimensions: 18 x 10 x 5 cm; 7.1 x 3.9 x 2 inches;
0.3 kg; 0.7 lbs.
Construction: High-impact Polycarbonate
Operating Environment: 10 - 40° C; 0 – 80% relative humidity non-condensing at temperatures to 31° C
EMC Rating: Radiation and conducted emissions and immunity per EN 60601-1-2
Performance Standards: ATS/ERS 2005 – properly measures all 26 flow-time waveforms; BTS; NIOSH; ACOEM; MDD
Quality Standards:  FDA QSR, ISO 13485:2003, MDD 93/42/EEC, EN 60601-1, 60601-1-1, 60601-1-2, 60601-1-4, CMDCAS/ Health Canada

 

Download Koko / DigiDoser Manual